Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Breast Disease(Electronic Edition) ›› 2009, Vol. 03 ›› Issue (05): 487-495. doi: 10.3877/cma.j.issn.1674-0807.2009.05.005

• Clinical Research • Previous Articles     Next Articles

Value of 18 F-FDG PET/CT imaging in the detection of breast cancer and axillary lymph node metastases

Xiang ZHU1, Wen-gui XU,1(), Wen-chao MA1, Dong DAI1, Lei ZHU1, Xiu-yu SONG1, Yan-jia ZHU1, Jian WANG1, Xiao-yuan MEN1   

  1. 1.Department of PET-CT,Cancer Institute and Hospital,Tianjin Medical University Tianjin 300060,China
  • Received:2009-05-11 Online:2009-10-01 Published:2024-12-04
  • Contact: Wen-gui XU

Abstract:

Objective

To investigate the value of 18F-fluorodeoxyglucose(FDG)PET/CT i maging in diagnosis of breast cancer and axillary ly mph node metastases.

Methods

According to the pathological diagnostic results 34 breast cancer patients were recruited for the study.Their 18F-FDG PET/CT i maging data were analyzed qualitatively by visual assess ment and semi-quantitatively by calculating maxi mu m standardized uptake values(SUVmax).The sensitivity,specificity and accuracy of the t wo methods were measured,Kappa test was used for the consistency of each of the t wo PET/CT diagnostic methods with pathological diagnosis,and the mean of SUVmax bet ween groups was compared using t wo independent samples t test.

Results

The comparison of the mean SUVmax bet ween the 2 groups showed the 18 F-FDGuptake was greater in the malignant breast lesion group than in the control group,with statistical significant difference bet ween the three groups(P=0.00).One case of pathological apocrine intraductal carcino ma,cancer in situ,was negatively uptaken by PET/CT.The qualitative analysis showed zero grade and semiquantitative analysis showed SUVmax as 1.5,because the lesion size was so s mall,<5-8 c m,which was beyond the uptake range of PET/CT.In diagnosing breast malignancy,the diagnostic accuracy,sensitivity and specificity of 18 F-FDG PET/CT qualitative analysis was 97.9%,97.7%and 100.0%,respectively;for the semi-quantitative analysis,when the cut-off point of SUVmax was set at 2.0,the sensitivity,specificity,and accuracy was 93.2%,100.0% and 93.6%,respectively.The kappa value was 0.85 for qualitative analysis,with excellent agreement,and 0.64 for semi-quantitatively.In detecting axillary ly mph node metastases,the sensitivity,specificity,and accuracy of qualitative analysis were 55.9%,96.1%and 90.1%,respectively;for semi-quantitative analysis,the cut-off point of SUVmax was set at 1.8 (referenced to literature),the sensitivity,specificity,and accuracy were 45.8%,97.0%and 89.3%,respectively;the kappa value was 0.57 for the qualitative analysis and 0.51 for semi-quantitative analysis.

Conclusion

For detecting malignant breast lesions with 18 F-FDGPET/CT,when the cut-off point of SUVmax was set at 2.0,semi-quantitative analysis is opti mal.For detecting axillary ly mph node metastases,both qualitative analysis(Kappa value=0.57)and semi-quantitative analysis(Kappa value=0.51)have median agreement with pathological diagnosis.

Key words: Breast neoplas ms, Axillary ly mph node, 18 F-fluorodeoxyglucose, Positron emission Tomography, Tomography, X-ray computed

京ICP 备07035254号-13
Copyright © Chinese Journal of Breast Disease(Electronic Edition), All Rights Reserved.
Tel: 0086-10-51322630 E-mail: jcbd@medmail.com.cn
Powered by Beijing Magtech Co. Ltd